03423220016
Sosyal Medya Hesaplarımız

Doppler Ultrasound U2 Prime Edition

 

Doppler Ultrasound U2 Prime Edition

The U2 is a practical, versatile color Doppler ultrasound system designed to address the imaging needs of clinicians and point-of-care specialists. With advanced signal processing, the U2 delivers exceptional image quality and un compromised diagnostic capabilities.

Features and Benefits

​Advanced Imaging Technologies

S​​peckle reduction technology ​

Improves contrast resolution while maintaining detail resolution

​​P​hase-inversion harmonic imaging​​

Reduces noise and clutter for optimum image quality

Spatial compounding

Multiple lines-of-sight improves contrast resolution

Multi-beam technology​

High frame-rate in all modes including color and Doppler

User-friendly ​Workflow

Intuitive control panel reduces learning curve

Smart PreSet – quickly adjust multiple setting to suit your patient type and imaging preferences

Multi-frequency Transducer Technology

Multiple 2-D, harmonic and color frequencies increases transducer utility

Doppler Ultrasound U2 Prime Edition

Supported Applications

Abdomen, Obstetrics, Gynecology, Endovaginal, Small Parts, Muculoskeletal, Vascular, Urology, Cardiology, Pediatrics

Compact, Mobile Cart Design

Exceptionally quick boot time

Built-in lithium battery

15″ High resolution LCD monitor

Multiple peripheral ports

Phase Inversion Harmonic Imaging

Harmonic signals are produced as ultrasound waves propagate through the body.  Because these signals are produced in the body, they are not influenced by artifact inducing fat near the skin surface. 

Consequently, an image formed using only the harmonic signal will have less clutter and can be more diagnostic.  With phase-inversion harmonics, pairs of ultrasound pulses with opposite phases are transmitted. 

When the signals received from inverted pulses are added together, the fundamental components are cancelled and only the harmonic signal remains.  This creates an image that is pure harmonic with reduction in clutter artifact that degrades the image.

Speckle Reduction Technology

Speckle reduction imaging uses real-time image processing to improve visualization of anatomy and pathology by reducing the speckle noise.   Edan’s speckle noise reduction imaging technology uses an advanced multi-scale anisotropic filtering algorithm. This imaging technology is excellent at separating the noise regions from the diagnostic image allowing complex filtering to be performed differently on noise versus true anatomic information thus producing an enhanced image.

Doppler Ultrasound U2 Prime Edition