Oxymag Transport Ventilatör Cihazı
OxyMag was developed with a design to keep up with the pace of a rescue squad. It is lightweight to facilitate transport and durable to absorb any possible impacts.
- Açıklama
Açıklama
Oxymag Transport Ventilatör Cihazı
Ventilation Modes
IDEAL FOR TRANSPORT
OxyMag combines the functions of an intensive care ventilator with the durability and lightness required for transport. Suitable for ventilation therapy for all age groups, from newborns to adults.
FLEXIBILITY AND SIMPLICITY
The intuitive interface reduces the adjustment time for parameters and alarms, allowing the rescue squad to attend to other activities that help with patient safety.
CAPNOGRAPHY AND OXYMETRY
By using the same equipment, it is possible to complement the monitoring to assist the patient’s mechanical ventilation, with the excellence and precision of MASIMO Capnography (EtCOî) and Oxymetry (SpO2İ.
LIGHTWEIGHT, COMPACT AND DURABLE
OxyMag was developed with a design to keep up with the pace of a rescue squad. It is lightweight to facilitate transport and durable to absorb any possible impacts.
Oxymag Transport Ventilatör Cihazı
Type and Size | TFT-LCD touchscreen 5,7″ |
Weight | 3,0 kg (6.6 lbs) |
Dimensions Wx H x D | 254 x 230 x 185mm (10 x 9.0 x 17.3 inch) |
Communication/lnterface | RS-232C ports |
Operating Conditions Specifications | |
Electrical power supply | 100 to 240 V, 50/60 Hz |
12 Vdc external | yes |
Battery | 6.5 hours |
O2 inlet: | 39 to 87 psi (270 to 600 kPa) |
Standard connection available | DISS (optional NIST) |
Temperature | -18to50°C (0 to 122°F) |
Barometric pressure | 600 to 1.100 cmH2Û (orhPa ou mbar) |
Relative humidity | 15 to 95% |
Oxymag Transport Ventilatör Cihazı | |
Type of patient | Adult, Pediatric and Neonatal |
Tidal volume | 20 to 2.500 ml |
Respiratory rate | D to 150 bpm |
Inspiratory flow | 0 to 150 l/min |
Rise time | 0 to 2,0 s |
Inspiratory time | 0,1 to 10 s |
Inspiratory pressure | 1 to 60 cmHîO (or hPa or mbar] |
Peep | 0 to 40 cmH20 (or hPa or mbar) |
Support pressure /Apsupp | OFF, 5 to 60 cmH20 (or hPa or mbar) |
Flow cycling [% of peak flow) | 5 to 80 % |
Trigger sensitivity (Pressure trigger) | OFF; -0,2 to -10 cmH20 (or hPa or mbar) |
Trigger sensitivity (Flow trigger) | OFF; 0,5 to 30 L/min |
I: E ratio | 1:4 a 4:1 |
O2 Concentration | OFF; 35 to 100% |
Type of inspiratory flow | Constant, decelerating, accelerating and sine |
Monitoring | |
Curve | PxT, FxT and VxT/Sp02/CO2 |
Loops | VxF, PxV |
Bargraph | Instant Pressure |
FİO2 | Galvanic cell |
Numerical value | Volume inhaled and exhaled, FİO2, dynamic compliance, intrinsic PEEP, resistance, O2 pressure, O2 consumption, EtCO2*, CO2*, SpOz**, heart rate**, perfusion index** |
* Using Capnography. ** Using Oximetry.
VCV/VCV-AC; PCV/ PCV-AC; PLV-AC; V-SIMV + PS; P-SIMV + PS; DualPAP/APRV; CPAP/PSV; NIV
Alarms
Oxymag Transport Ventilatör Cihazı
Minute volume | high / low |
Respiratory rate | high / low |
Inspiratory pressure | high / low |
Peep | high / low |
Apnea time | OFF, 5 to 60 s |
Automatic alarm settings | OFF, 10%, 20% and 30% |
Oxymag Transport Ventilatör Cihazı
Oxymag Transport Ventilatör
Stand by | on/off |
Manual cycles | yes |
Freeze | yes |
Sigh | yes |
Automatic barometric compensation | yes |
Mobile base, wall support, transport system (bags), capnography and oximetry. DC / DC cable, Air and O2 blender
Fastening and transport systems